img_9451_11-removebg-preview

Diesel generator set ESE 225 TI-V

Amperage
293.6
Power (kVA)
225 / 205.5
Power (kW)
180 /162
Standard voltage
400 / 230 V
Speed
1500 rpm
Power factor
0,8
Fuel
Motorina
Engine manufacturer
Iveco
Request quote
Series Power KVA Amperage Engine manufacturer Power KW
ESE 385 TI-V385 / 346.5502.4Iveco308 / 277
ESE 330 TI-V330 / 297430.7Iveco264 / 238
ESE 275 TI-V275 / 247.5358.9Iveco220 / 198
ESE 225 TI-V225 / 205.5293.6Iveco180 /162
ESE 165 TI-V165 / 148.5215.3Iveco132 / 119
ESE 100 TI-V100 / 90214Iveco80 / 72
ESE 90 TI-V90 / 81117.5Iveco72 / 65
ESE 440 TI-V440 / 396574.2Iveco352 / 317
ESE 60 TI-V6,0 / 5,4783Iveco48 / 43
ESE 50 TI-V50 / 4565.3Iveco40 / 36
ESE 440 TI-V40/3652.2Iveco32 / 29

Technical details

The ESE 225 TI-V diesel generator produced by Endress Group Romania under the Zenessis brand is equipped with IVECO Stage V N67TEVP05 engine, Marelli MXB-E 250 SB4 / ECO 220 KW alternator and ComAp INTELILITE AMF 25 control system, which ensures the starting of the generator, the control of the parameters, in manual or automatic system. The generator can be supplied with remote control and monitoring as well as other options. Zenessis power generators are guaranteed for 36 months, up to 2000 operating hours.

Standard features

Control & command panel with metal measuring & control devices, IP 54 protection rating
Static battery charger
Dynamic battery charging alternator
Chassis with fuel tank sized for. 8 hours autonomy
Vibration dampers
Fuel level measuring device
Chassis with fuel tank sized for 8hrs of autonomy
Vibration dampers
Fuel level measuring device
Electrical lines protected with tubing & gland
Residential silencer
Thermostat heater ordered for. coolant
Oversized start battery
Emergency stop button
Protective pads
Metal hinges
Access doors with locks
Protective pads
Metal hinges
Access doors with locks
Crane or forklift handling system
Flameproof and soundproof insulation

Iveco diesel engine

Engine

ModelN67TEVP05
ModelIVECO Stage V
No. of cylinders & arrangement6 in linie
Cooling systemWith liquid
Displacement (l)6,7
Injection systemDirect with turbine
Maximum standby power (kWm)200
Speed (rpm)1500
Inside diameter & stroke (mm)104 x 132
Compression factor17:1
Regulator Electronic
Total oil capacity (l)16
Engine cooling agent capacity (l)28
Fuel consumption at 100% load in prime mode (l / h)41.6

Alternator

Alternator Marelli / Strathon

ModelMXB-E 250 SB4 or ECO 220 KW
Frequency (Hz)50
ConceptBrushless, 4 poles
Phases3 + n
Voltage (V)400 / 230
Insulation classH
Excitation systemElectronic
Performance93%
ProtectionIP23
Certification testEN 10204 : 2001

Control panel

Made in metal box, IP54 degree, with lock. The control panel is equipped with ComAp Inteli Lite NT AMF25 control module, with the possibility to start and stop the generator set, both in automatic and electric mode. The control panel monitors the power grid and can command and control the ATS panel (automatic transfer switch).

Control panel standard specifications :

The command and control panel is mounted inside the housing, in a metal box with IP 54, provided with
viewing window, equipped with:

Modul comanda Inteli Lite NT AMF 25
Static battery charger
Emergency stop button & circuit breaker fuses control
Overcurrent differential protection
Protection relays

Control panel

1. Left button
2. Right button
3. Horn Reset button
4. Fault Reset button
5. Up button
6. Page button
7. 7. Down button
8. Enter button
9. Start button
10. Stop button
11. GCB button. Works in MAN and TEST modes only 12. MCB button. Works in MAN and TEST modes only
12. MCB button. 12. MCB button. Works in MAN and TEST modes only
13. Generator status indicator
14. GCB On. Green LEDs are on if GCB is closed and Gen-set is healthy
15. Load
16. Graphic B/W display, 132 x 64 pixeli
17. Mains status indicator
18. MCB On. Green LEDs are on if MCB is closed and Mains is healthy

Configuration

1. Inteli Lite NT AMF 25 control module
2. Circuit Breaker protection
3. Locks
4. Alarm
5. START button ON / OFF
6. Hinges
7. Maintenance schedule
8. Metal box

Command module standard specifications:

Configuration

download-_4_
– Microprocessor control
– Display LCD 132 x 64 pixeli
– Programming possibility on the front panel as well as via PC software
– Soft touch navigation and control buttons
– Remote communication via USB plug or optionally via RS232, RS485, Ethernet or sms message
– 180 events memory with date and time
– Maintenance programming 3 levels
– Engine heater control -optional

Displays:

Engine – engine speed; oil pressure; coolant temperature; running time; battery voltage; maintenance date
Alternator – voltage (L – L, L – N); current (L1 – L2 – L3); frequency; kW; Pf; kVAr; kWh,kVAh, kVarh; phase sequence.
Main grid – voltage (L-L, L-N); frequency; main grid ready; main grid disconnected; generator set ready; generator set disconnected; active power kW; apparent power kVA; reactive power kVAR; power factor; phase sequence.
Warnings – : battery mischarge, low battery voltage, missed shutdown, low fuel level, overload, phase reversal, speed sensor fault.
Alarms – low oil pressure, high engine temperature, under / over voltage, under / overfrequency, under / overvoltage, ECU fault -optional.
Status displays – failed start, emergency stop, low oil pressure, high engine temperature, under/overload, under/over frequency, under/over voltage, oil sensor fault, phase rotation, overload, group overcurrent, phase reversal.

Static battery charger:

manufactured with high efficiency TSD technology. Protected for short- circuit currents, it can be used as a current source, input voltage 196-264 V, output voltage 27.6 V / 5A or 13.8 V / 5A.

Standards

Electrical safety / EMC, BS EN 60950; BS EN 60950 – 6 – 2 EMC; BS EN 61000 – 6 – 4 EMC.

Housing

Made of galvanized steel, painted in electrostatic field, soundproofed. It is modularly designed with in-door access doors on all sides of the generator. The exhaust pan is residential type, mounted inside the casing.

The housing are designed to optimize the cooling of the engine and alternator assembly, and can be mounted outdoors, providing protection against weathering and low noise levels. Painting is done with polyurethane paint with UV protection.

Housing

ese
1. Command module
2. View window
3. Access door for control module
4. Points for crane lifting (optional)
5. Spaces for handling with the forklift
6. Engine and alternator access door
7. Air intake grills
8. Handles provided with locks
9. Fuel supply bus (optional)
10. „Sleigh chassis” fitted with lifting/pulling holes
11. Emergency button
12. Exhaust Gas Valve
13. Cable access space
14. Hot air outlet grills
15. Protective pads

Dimensions and weight

Dimensions and weight of open genset

Sizes (length x width x height) (mm)3190 x 1180 x 2400
Weight (kg)2000
Fuel tank capacity (liters)200
Ambient noise level (at 7m distance)82 db

Dimensions and weight of the closed genset

Sizes (length x width x height) (mm)3500 x 1270 x 2100
Weight (kg)2680
Fuel tank capacity (liters)200
Ambient noise level (at 7m distance)70 db

Optional features

Electrical panel anti-condensation heating system
Fuel / oil heating system
Coolant heating circulation pump
Oil drain pump
Motorized ATS, ENDRESS patented invention – OSIM patent 00048 / 2015
AAR transfer panel with 3/4 poles
3/4 pole differential protection
Sokets 400 V/ 230 V
Fuel filter with water detection
Bypass panel – ENDRESS patented invention – OSIM patent 00010 / 2012
Trailer
Start by remote control
Groundless protection
Interior lightings with switches operated at doors opening
Liquid retention tray
Liquid leakage detection sensor
Remote monitoring & control system
External fuel feed nozzle with lock
Pocket system integrated in the chassis for lifting with forklift
Fire extinguisher with internal housing support
Super soundproof housing
Intake air heating spark plug
Grounding electrodes
Fuel transfer automatic pump
Mobile distribution panel with 4 sockets
Cable reel
Fire detector with automatic shutdown generator set
Fire extinguishing system with inert gas

Optional: RAR approved auto trailer

Model: EGR 6000

Endress Group Romania S.R.L. certifications:

ISO 9001 : 2008, ISO 14001 : 2005, ISO 18001 : 2008.

ZENESSIS generators are CE compliant, and are tested according to the EU legislation on noise levels 2000 / 14 / EC.

Reference ambient conditions: 1000 mbar; 25° C; 30% relative humidity; power according to ISO 3046 / ISO 8528 standards

Prime power (PRP) – ISO 8528

Primary power (PRP) – is the continuous power that a generator is capable of supplying continuously while supplying a variable electrical load when operating for an unlimited number of hours per year under agreed operating conditions, within the maintenance intervals and procedures prescribed by the manufacturer.

Standby power (ESP) – ISO 8528

Standby power (ESP) is the maximum power available at a variable load, under the operating conditions provided, that a generator is able to provide in case of power failure or under test conditions, maintenance intervals and procedures being performed as prescribed by the manufacturer.

Fill in the offer request:

Endress Zenessis Group manufactures power generators and UPS uninterruptible power supplies under the ZENESSIS brand!

© Endress Zenessis Group, Zenessis, 2022