kubota-stage5

Diesel generator set ESE 17 TKV-V

Engine manufacturer
Kubota
Fuel
Amperage
Power (kVA)
17 / 15
Power (kW)
13,6 / 12
Request quote
Series Power KVA Amperage Engine manufacturer Power KW
ESE 17 TKV-V17 / 15Kubota13,6 / 12
ESE 20 TKV-V20 / 1826Kubota16 / 14,5

Technical details

Kubota Engine

image 1 (7)-Photoroom 1-min

Diesel Engine

ModelKUBOTA
ModelD1703-M-E4-BG2
Pollution standard EU STAGE V
Number of cylinders 3
Cooling system With liquid
Induction systemNatural aspiration
Displacement (l)1,64 (l)
Standby power (kWm)20,1 KWh
Speed (rpm)1500 rpm
Bore & Stroke (mm)87 x 92,4 mm
Regulator Electronic
Total oil capacity (l)7 (I)
Engine coolant & radiator capacity5,5 (l)
Fuel consumption at 100% prime load4,4 (l / h)

Alternator

Alternator Marelli

76
ModelECO-17KW
Frequency (Hz)50 Hz
ConceptBrushless, 4 poles
Phases3
Voltage (V)400 / 230 V
Insulation classH
Excitation systemElectronic
Performance93%
ProtectionOverload
Test CertificationEN 10204:2001

Control panel

Made in metal box, IP54 degree, with lock. The control panel is equipped with ComAp Inteli Lite NT AMF9 control module, equipped with the possibility to start and stop the generator set, both in automatic and electric mode. The control panel monitors the power grid and can command and control the ATS panel (automatic transfer switch).

Control panel standard specifications :

The command and control panel is mounted inside the casing, in a metal box with IP 54, equipped with a viewing glass, equipped with:

Lite AMF 9,
Static battery charger
Emergency stop button & circuit breaker fuses control
Overcurrent differential protection
Protection relays

Control panel

Picture1
1. Left button
2. Right button
3. Start button
4. Fault Reset button
5. Stop button
6. Up button
7. 7. Down button
8. Page button
9. Enter button
10. The button GCB. Works only in MAN and test modes
11.MCB button. Works only in MAN and test modes
12. Consumers
13. GCB On. Green LEDs are on if GCB is closed and Gen-set is healthy
14. MCB On. The green LEDs are in the “on” state
if the MCB is closed and the network is within the preset parameters.
15.Indicator Status Generator
16. Network Status Indicator
17. Display, 132 x 64 pixels

Command module standard specifications:

Microprocessor control
132 x 64 pixeli LCD display
Programming on front panel as well as through PC software
Control buttons and soft touch navigation
Remote communication via USB or with optional modules via RS232, RS485, Ethernet or SMS
Store 180 events with date and time
Maintenance programming 3 levels
Engine heater control –Optional

Configuration

fafafafsvacac

Configuration

1.Inteli Lite NT AMF 9 control module
2. Circuit Breaker protection
3. Locks
4. Alarm
5. START button ON / OFF
6. Hinges
7. Maintenance schedule
8. Metal box

Displays:

Engine – engine speed; oil pressure; coolant temperature; running time; battery voltage; maintenance data.
Alternator – voltage (L – L, L – N); current (L1 – L2 – L3); frequency; kW; Pf; kVAr; kWh,kVAh, kVarh; phase sequence.
Main network – voltage (L – L, L – N); frequency, mains ready; mains off; generator set ready, generator set disconnected, active power kW, apparent power kVA, reactive power kVA r, power factor, phase sequence.
Warning – battery faulty charging, low battery voltage, fail to stop, low fuel level, overload, phase reversing, speed sensor failure.
Alarms – low oil pressure, high engine temperature, under / over voltage, under / overfrequency, under / overvoltage, ECU fault -optional.
Status displays – missed start, emergency stop, low oil pressure, high engine temperature, under / overspeed, under / overfrequency, under / overvoltage, oil sensor, phase rotation, overload, overcurrent group, phase reversal.

Static battery charger:

Made with TSD technology, with high efficiency. Protected for short- circuit currents, it can be used as a current source, input voltage 196-264 V, output voltage 27.6 V / 5A or 13.8 V / 5A.

Standards

Electrical safety / EMC, BS EN 60950; BS EN 60950 – 6 – 2 EMC; BS EN 61000 – 6 – 4 EMC.

Housing

Made of galvanized steel, painted in electrostatic field, soundproofed. It is modularly designed with in-door access doors on all sides of the generator. The exhaust pan is residential type, mounted inside the casing.

The housing are designed to optimize the cooling of the engine and alternator assembly, and can be mounted outdoors, providing protection against weathering and low noise levels. Painting is done with polyurethane paint with UV protection.

Housing

AD288093-81BE-4D9F-AB0C-B255DB5734AC
1. Command module
2. View window
3. Access door for control module
4. Points for crane lifting (optional)
5. Spaces for handling with the forklift
6. Engine and alternator access door
7. Air intake grills
8. Handles provided with locks
9. Fuel supply bus (optional)
10. „Sleigh chassis” fitted with lifting/pulling holes
11. Emergency button
12. Exhaust Gas Valve
13. Cable access space
14. Hot air outlet grills
15. Protective pads

Dimensions and weight

Dimensions and weight of open genset

Sizes (length x width x height) (mm)1600 x 900 x 1715
Weight (kg)480
Fuel tank capacity (liters)50
Noise level (at 7m distance)85 db

Dimensions and weight of the closed genset

Sizes (length x width x height) (mm)1870 x 1010 x 1415
Weight (kg)580
Fuel tank capacity (liters)50
Noise level (at 7m distance)72 db

Standard features

Control & command panel with metal measuring & control devices, IP 54 protection rating
Static charger for. battery
Dynamic alternator charging batteries ori
Chassis with fuel tank sized for. 8 hours autonomy
Vibration dampers
Fuel level measuring device
Electrical lines protected with tubing & gland
Residential silencer
Thermostat heater ordered for. coolant
Oversized start battery
Emergency stop button
Protective pads
Metal hinges
Access doors with locks
Crane or forklift handling system
Flameproof and soundproof insulation

Optional features

Anti-condensation heating system. electrical panels
Fuel / oil heating system
Oil drain pump
Motorized AAR, patented invention ENDRESS-Brevet OSIM 00048/2015
AAR transfer panel with 3/4 poles
3/4 pole differential protection
400 V/230 V socket
Coolant heating circulation pump
Fuel filter with water detection
Detour board – patented invention ENDRESS – Patent OSIM 00010/2012
Trailer
Start by remote control
Groundless protection
Interior lightings with switches operated at doors opening
Liquid retention tray
Liquid leakage detection sensor
External nozzle for fuel supply
Remote monitoring & control system
Forklift pocket system integrated in the chassis
Fire extinguisher with internal housing support
Super soundproof housing
Intake air heating spark plug
Fire extinguishing system with inert gas
Fire detector with automatic shutdown generator set
Fuel transfer automatic pump
Grounding electrolysis
Cable reel
Mobile distribution panel with 4 sockets

Optional: RAR approved auto trailer

Model: EGR 1000

Image 20.02.2024 at 15.21

Endress Group Romania S.R.L. certifications:

ISO 9001 : 2008, ISO 14001 : 2005, ISO 18001 : 2008.

ZENESSIS generator sets are CE compliant, and are tested according to EU noise legislation 2000/14/EC.

Reference ambient conditions: 1000 mbar; 25° C; 30% relative humidity; power according to ISO 3046 / ISO 8528 standards

Prime power (PRP) – ISO 8528

Primary power (PRP) – is the continuous power that a generator is capable of supplying continuously while supplying a variable electrical load when operating for an unlimited number of hours per year under agreed operating conditions, within the maintenance intervals and procedures prescribed by the manufacturer.

Standby power (ESP) – ISO 8528

Standby power (ESP) is the maximum power available at a variable load, under the operating conditions provided, that a generator is able to provide in case of power failure or under test conditions, maintenance intervals and procedures being performed as prescribed by the manufacturer.

Fill in the offer request: