picture1_2_upscayl_8x_realesrgan-x4plus-removebg-preview

ZC 3KR

Engine manufacturer
Zenessis
Standard voltage
230 / 240 V
Fuel
Electric
Power factor
0,9
Power (kVA)
3
Power (kW)
2.7
Request quote
Series Power KVA Amperage Engine manufacturer Power KW
ZNG 1010N/AZenessis10
ZNG 1515N/AZenessis15
ZNG 4040N/AZenessis40
ZRT 120N/AN/AZenessis
ZMT 20N/AN/AZenessisN/A
ZMT 10N/AN/AZenessisN/A
ZRM 1010N/AZenessis10
ZRM 6N/AN/AZenessis
ZRM 3N/AN/AZenessis
ZRM 2N/AN/AZenessis120
ZC 3 KR3N/AZenessis2.7
ZRM 3 ZCR3N/AZenessisN/A
ZC 5KN/AN/AZenessis5
ZRM 1 STN/AN/AZenessis120
ZRM 1N/AN/AZenessis120

Technical specifications

Input frequency50/60 Hz
UPS operating temperatures0°C ÷ 40°C
Power (kVA)3
Input power factor>0,99
TechnologyTRUE ON LINE Double conversion
ClassificationVFI-SS-111 (EN 62040-3)
Number of phases1:1
ModelZC 3KR
Power3 kVA / 2.7 kW
Number of input : output phases 1:1

Entry

Voltage (V) 220 / 230 / 240 VAC
Voltage range at 100% load-35% ÷ +35%
Frequency (Hz)50/60 Hz
Frequency range-20% ÷ +20%
THDi<3%
Input power factor.≥0,99

Exit

Voltage (V)220 / 230 / 240 VAC
Output power factor0.9
Static/dynamic voltage regulation±1% / ±3%
Frequency (Hz)50/60 Hz ± 3 Hz with automatic synchronisation
Overload capacity inverter110% – no limit, 130% – 5 min., 140% – 30 sec., >140% – 1,5 sec.
Efficiency in On-line mode>92%
Randament în modul Eco99%
Terminal platen/a (Plug & Play)
Peak factor3:1
Transfer type0 ms AC to DC
Type and number of socketsIEC320-C13 x 8 , IEC320-C19 x 1 , IEC Jumpers x 2 with possibility to control output connectors individually or in groups

Batteries

ModelSigilate etanş, cu electrolit suspendat în fibră de sticlă (AGM) şi supapă de reglare (VRLA), inclus
Hermetically sealed, with glass-fibre suspended electrolyte (AGM) and regulating valve (VRLA), included15 minutes at 50% charge, 6 minutes at 100% charge
Scalabilitypossibility to add modules
Cold startyes
Loading time4 hours at 90% capacity (configurable)

Weight and dimensions

UPS dimensions and weight (W x D x H)438 x 630 x 88 (2U)
Dimensions and weight of battery module (W x D x H)438 x 630 x 133 (3U)
Battery module weight ( Kg)40.8

Communications

Operation indicatorLCD + LED indicators, audible alarms (battery on, battery low, battery replacement)
CommunicationsStandard: USB tip A, RS232, TVSS, Slot inteligent, RJ-45 Serial, REPO
Optional: Card AS400

Ambient

Noise level<45 dB
Operating temperature for UPS0°C ÷ 40°C
Recommended operating temperature for UPS15°C ÷ 25°C
Storage temperature-25°C ÷ 55°C
Humidity0 ÷ 95% (fără condensare)

Certification test

StandardsEN 62040-2:2006
SafetyEN 62040-1:2008 + A1:2013, CE, EN 62040-3 :2001, EN 60950-1, EN61000-3-2 :2014
SustainabilityRoHS

Options

SNMP cards
Ambient sensor (EMD)
Bypass maintenance
REPO
Cards AS400
Ekstra batteritilstand
Kit on 19″ saddle
Outlet plug fixing piece
Cable for management console, external environment with monitoring and control software

Fill in the offer request:

Endress Zenessis Group manufactures power generators and UPS uninterruptible power supplies under the ZENESSIS brand!

© Endress Zenessis Group, Zenessis, 2022